Termékek prima keleti s p (4)

Fali tűzcsap ajtó EI 60 - tűzcsap

Fali tűzcsap ajtó EI 60 - tűzcsap

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboard Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018EN 1634-1: +A1: 2018 Fire dampers EI 60 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.
Kukorica EC-GISELLA index 260 - Árazás hektáronként

Kukorica EC-GISELLA index 260 - Árazás hektáronként

EVAGRI sélectionne des variétés de maïs hybride sur l’ensemble du cycle de végétation pour favoriser au maximum le tonnage de matière sèche à l’hectare. Les variétés destinées au maïs ensilage sont également sélectionnées sur les critères de digestibilité et la valeur énergétique pour une meilleure valorisation animale. Indice fao : 260-270 demi precose corne denté à tendance dentée Grain, Ensilage et Biogaz en CCM
Hordozható Fúrók - Partnerünk ELSA - Fúrók

Hordozható Fúrók - Partnerünk ELSA - Fúrók

Pour accéder au site ELSA, cliquez ci- après
Fali tűzcsap ajtó 120 MN - tűzcsap

Fali tűzcsap ajtó 120 MN - tűzcsap

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018 Fire dampers EI 120 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 120. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.